5.DETAILS OF PARAMETERS B-65270EN/05
- 384 -
#7 #6 #5 #4 #3 #2 #1 #0
2686 (FS15i)
DBTLIM EGBFFG EGBEX POA1NG WSVCP
2273 (FS30i, 16i)
WSVCP (#0) When the simple synchronous control is used, the loop integrator of
the master axis :
0: Can not be copied to the slave axis.
1: Can be copied to the slave axis.
(Specify only the slave axis.)
[Reference item] Subsection 4.18.9
POA1NG (#4) In the calculation of the observer coefficient (POA1), the load inertia
ratio (LDINT) is:
0: Considered.
1: Not considered.
EGBEX (#5) The EGB automatic phase matching function is:
0: In the normal mode (deceleration not performed between the
master and detector).
1: In the extended mode (deceleration performed between the
master and detector).
EGBFFG(#6) FFG is:
0: Not considered in the EGB ratio.
1: Considered in the EGB ratio.
HP2048 (#0) During brake control, the torque limit setting function is:
0: Disabled.
1: Enabled.
[Related parameters] 2788 (15i), 2375 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
2687 (FS15i)
HP2048
2274 (FS30i, 16i)
HP2048 (#0) A 2048-time interpolation circuit (position detection circuit H or C) is:
0: Not used.
1: Used .
[Reference item] Subsection 2.1.4 and Section 4.14
#7 #6 #5 #4 #3 #2 #1 #0
2688 (FS15i)
ASYN RCNCLR 800PLS
2275 (FS30i, 16i)
800PLS (#0) When the RCN723 or RCN223 is used, the reference counter setting is
made in reference to:
0: 1/8 turns of the detector.
1: 1 turn of the detector.
[Reference item] Subsection 2.1.4