5.DETAILS OF PARAMETERS B-65270EN/05
- 388 -
☆: Parameters set up automatically at initialization
★: Parameters that can be kept at the automatically set values
Parameter number
Series 15i
Series 30i, 16i,
and so on
Details
1990 2097 Static friction compensation stop parameter
☆ → 4.6.8
1991 2098 Current phase lead compensation coefficient
★ Motor-specific
1992 2099 N pulses suppression function
★ → 4.4.4
1994 2101 Overshoot compensation valid level
☆ → 4.7
1995 2102 Final clamp value for the actual-current limit
★ Motor-specific
1996 2103
Track back amount applied when an unexpected disturbance
torque is detected
☆ → 4.12
1997 2104
Unexpected disturbance torque detection alarm level (cutting
when switching is used)
☆ → 4.12
1998 2105 Torque constant
☆ → 4.15
1700 2107 Velocity loop gain override
☆ → 4.3
1702 2109
Fine acc./dec. time constant (rapid traverse when switching is
used)
☆ → 4.3 and 4.8.3
1703 2110 Magnetic saturation compensation
★ Motor-specific
1704 2111 Torque limit at deceleration
★ Motor-specific
1705 2112 Linear motor AMR conversion coefficient 1
☆ → 4.14
1706 2113 Resonance elimination filter 1: attenuation center frequency
☆ → 4.5.2
1725 2114
Backlash acceleration function : acceleration amount override
2-stage backlash acceleration function : stage 2 acceleration
amount override
→ 4.6.6
→ 4.6.7
1726 2115 For internal data output: Usually to be kept at 0.
1727 2116
Unexpected disturbance torque detection : dynamic friction
cancel
→ 4.12
1729 2118
Dual position feedback
Semi-closed/full-closed error overestimation level
→ 4.5.7
1730 2119 Variable proportional gain function in the stop state : Stop level → 4.4.3, 4.5.4
1732
1733
2121
2122
Series 9081
Series 90B0 and 9096 are not applied to this parameter.
1737 2126 Tandem control/position feedback switching time constant → 4.18.7
1735 2127 Non-interference control coefficient (NINTCT)
★ Motor-specific
1736 2128 Coefficient for magnetic flux weaken compensation (MFWKCE)
★ Motor-specific
1752 2129 Coefficient for magnetic flux weaken compensation (MFWKBL)
★ Motor-specific
1753
1754
1755
2130
2131
2132
Smoothing compensation performed twice per pole pair
Smoothing compensation performed four times per pole pair
Smoothing compensation performed six times per pole pair
☆ → 4.14.3
1756 2133
Coefficient for phase lag compensation during deceleration
(PHDLY1)
★ Motor-specific
1757 2134
Coefficient for phase lag compensation during deceleration
(PHDLY2)
★ Motor-specific
1760 2137
2-stage backlash acceleration function : stage 1 acceleration
amount override
→ 4.6.7
1761
1762
2138
2139
Linear motor AMR conversion coefficient 2
Linear motor AMR offset
→ 4.14
1765 2142
Unexpected disturbance torque detection alarm level in rapid
traverse
→ 4.12.2
1766 2143 Fine acc./dec. time constant 2 (in cutting) → 4.3, 4.8.3
1767 2144 Position feed-forward coefficient for cutting → 4.3, 4.6.4, 4.8.3
1768 2145 Velocity feed-forward coefficient for cutting → 4.3, 4.6.4, 4.8.3