APPENDIX 3 ERROR MESSAGES
8. MNEMONIC EDITING
8.1 Mnemonic Editing (System Parameters >
Message
Invalid qualifier.
Description and action to be taken
- System parameter is followed by invalid
character(s).
Unknown data number.
- Data number was specified that does not exist in
the system parameters.
Illegal value.
Out of value.
- System parameter contains invalid numerical data.
- System parameter contains out-of-bound numerical
data.
Expected a multiple of 5.
Expected a multiple of 2.
- System parameter required to be a multiple of 5 is
not a multiple of 5.
- System parameter required to be a multiple of 2 is
not a multiple of 2.
Illegal character(s).
Data not found.
Too many characters in 1 line.
- System parameter contains invalid character(s).
- There is no system parameter data.
- System parameter contains a line of data that
exceeds the maximum allowed number of
characters.
Illegal data number.
Too long strings.
Illegal address
Expected parameter(s)
Illegal OP. PANEL (PARAMETER)
Proceed to discompile using ‘NO’.
- System parameter contains invalid data number(s).
- System parameter contains character data that
exceeds the maximum length.
- System parameter contains an invalid address.
- System parameter is missing or incomplete.
- As OP.PANEL (parameter) of the system
parameters is invalid, it is assumed to be “NO”
and operation continues.
A3-22