B–63833EN–1/02
5. AUTOMATIC OPERATION
219
3017 Output time of reset signal RST
[Data type] Byte
[Unit of data] 16 ms
[Valid data range] 0 to 255
To extend the output time of reset signal RST, the time to be added is
specified in this parameter.
RST signal output time = time required for reset + parameter value
16 ms
#7
MCL3203
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
MCL Whether a program prepared in the MDI mode is cleared by reset
0: Not deleted
1: deleted
#7
3402
#6
CLR
#5 #4 #3 #2 #1 #0
[Data type] Bit
CLR Reset key on the MDI panel, external reset signal, reset and rewind signal,
and emergency stop signal
0: Cause reset state.
1: Cause clear state.
#7
CLV6001
#6
CCV
#5 #4 #3 #2 #1 #0
[Data type] Bit
CCV Custom macro’s common variables Nos. 100 through 149
0: Cleared to “vacant” by reset
1: Not cleared by reset
CLV Custom macro’s local variables Nos. 1 through 33
0: Cleared to “vacant” by reset
1: Not cleared by reset