B–63833EN–1/02
9. SPINDLE SPEED FUNCTION
456
Spindle motor speed
Max. speed (4095, 10V)
Spindle motor max.
clamp speed
(Parameter No. 3736)
Spindle motor minimum
clamp speed
(Parameter No. 3735)
Spindle speed (S command)
NOTE
If the function of constant surface speed control or bit 4
(GTT) of parameter No. 3706 is specified, this parameter is
invalid.
In this case, the maximum clamp speed of spindle motor
cannot be specified. However, the maximum spindle speed
can be specified by the following parameters.
Parameter No.3772 (for the first axis)
Parameter No.3802 (for the second axis)
Parameter No.3822 (for the third axis)
3740 Time elapsed prior to checking the spindle speed arrival signal
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 225
Set the time elapsed from the execution of the S function up to the
checking of the spindle speed arrival signal.