B–63833EN–1/02
11. PROGRAM COMMAND
675
[Classification] Output signal
[Function] Reports that the positioning of G81 has been completed in the external
motion function, and that a special external operation is required.
[Output condition] For details of the output condition and procedure, see the ”basic
procedure”, described previously.
For details of completion signal FIN, see section 8.1.
#7 #6 #5 #4 #3 #2 #1 #0
F008 EF
#7 #6 #5 #4 #3 #2 #1 #0
5101 EXC
[Data type] Bit
EXC G81:
0 : Specifies a drilling canned cycle
1 : Specifies an external operation command
CAUTION
1 When this function is used, canned cycles (G73, G74, G76,
and G82 to G89) cannot be used.
2 When the high–speed M, S, T, or B interface is used, the
signals used by this function are transferred in high–speed
mode. See Section 8.4.
Series 0i–B
OPERATOR’S MANUAL
(M series) (B–63844EN)
II.13.7 External operation function (G81)
Series 0i Mate–B
OPERATOR’S MANUAL
(M series) (B–63864EN)
II.13.4 External operation function (G81)
Signal
External Operation
Signal
EF<F008#0>
Signal address
Parameter
Caution
Reference item