B–63833EN–1/02
9. SPINDLE SPEED FUNCTION
485
1820 Command multiply for each axis (CMR)
[Data type] Byte axis
D When command multiply is 1/2 to 1/27
Set value=
1
(Command multiply)
+100 [Valid data range: 102 to 127]
D When command multiply is 0.5 to 48
Set value = 2 command multiply [Valid data range: 1 to 96]
Set this parameter to 2 for spindle positioning.
1821 Reference counter size for each axis
[Data type] Two–word axis
[Valid data range] 0 to 99999999
Set the size of the reference counter.
Set this parameter to 10000 for spindle positioning.
1826 In–position width for each axis
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
Set the in–position width for each axis.
1828 Positioning deviation limit for each axis in movement
[Data type] Two–word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Set the positioning deviation limit in movement for each axis.
1829 Positioning deviation limit for each axis in the stopped state
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
Set the positioning deviation limit in the stopped state for each axis.