B–63833EN–1/02
12. DISPLAY/SET/EDIT
731
[Classification] Output signal
[Function] Indicates that a dynamic graphics display (animated graphics display) is
being drawn for check purposes.
[Operation] The signal becomes 1 when:
D Check drawing begins.
The signal becomes 0 when:
D A reset occurs after check drawing has ended.
#7
F062
#6 #5
CKGRP
#4 #3 #2 #1 #0
#7 #6 #5 #4 #3 #2 #1 #0
MVG3003
[Data type] Bit
MVG While drawing using the dynamic graphics function (with no machine
movement), the axis–in–movement signal is:
0 : Output
1 : Not output
#7 #6 #5 #4 #3 #2 #1 #0
6500 NZM
DPO
DPA
[Data type] Bit
DPA Current position display on the graphic display screen
0 : Displays the actual position with tool nose radius compensation
1 : Displays the programmed position
DPO Current position on the workpiece drawing or tool path drawing screen
0 : Is not displayed
1 : Displayed
When the background graphic function is used, modal information
items F, S, T, and current position are displayed. When the [POS] soft
key is selected in dynamic graphic display mode, only the current
position is displayed.
Signal
Check
drawing–under–way
signal
CKGRP <F062#5>
Signal address
Parameter