13. INPUT/OUTPUT OF DATA
B–63833EN–1/02
818
[Classification] Input signal
[Function] This signal indicates that an alarm has been issued while the power mate
CNC was performing data input/output.
[Operation] This signal is set to 1 upon the issue of an alarm while the power mate
CNC is performing data input/output.
This signal is a Power Mate state signal. The corresponding power mate
CNC side signal is RPALM <F223#3>.
[Classification] Input signal
[Function] This signal indicates that the power mate CNC is performing background
editing.
[Operation] This signal is set to 1 when the power mate CNC is performing
background editing.
This signal is a Power Mate state signal. The corresponding power mate
CNC side signal is BGEACT <F223#4>.
[Classification] Input signal
[Function] This signal indicates that the Power Mate state signals are valid.
[Operation] When this signal is set to 1, the control unit operates as follows:
– All Power Mate state signals become valid.
For data input/output between the Series 0i/0i Mate and power mate CNC,
the Power Mate state signals are used. For this purpose, ladder program
processing is required. Upon the completion of ladder program
processing, I/O Link confirmation signal IOLACK is set to 1 to make the
Power Mate state signals active.
Power Mate read/write
alarm signal
BGIALM <G092#3>
Power Mate background
busy signal
BGEN <G092#4>
I/O Link confirmation
signal
IOLACK <G092#0>