B–63833EN–1/02
11. PROGRAM COMMAND
695
#7 #6 #5 #4 #3 #2 #1 #0
SCR5400 XSC
[Data type] Bit
XSC Axis scaling and programmable mirror image
0 : Not active (The scaling magnification is specified by P.)
1 : Active
SCR Scaling magnification unit
0 : 0.00001 times (1/100,000)
1 : 0.001 times
#7 #6 #5 #4 #3 #2 #1 #0
5401 SCLx
[Data type] Bit axis
SCLx Scaling for every axis
0 : Not active
1 : Active
5411 Default scaling magnification value
This parameter can be set at “Setting Screen.”
[Data type] Two–word
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter No. 5400)
[Valid data range] 1 to 999999
This parameter sets the scaling magnification. This setting value is used
when a scaling magnification (P) is not specified in the program.
NOTE
Parameter No. 5421 becomes valid when scaling for every
axis is valid. (XSC, #6 of parameter No. 5400 is “1”.)
Parameter
D Setting valid/invalid and
magnification of scaling
D Valid/invalid setting to
each axis scaling
D Default scaling
magnification value