B–63833EN–1/02
15. PMC CONTROL FUNCTION
941
#7
EPN7G024
#6
EPN6
#5
EPN5
#4
EPN4
#3
EPN3
#2
EPN2
#1
EPN1
#0
EPN0
#7
EPNSG025
#6 #5
EPN13
#4
EPN12
#3
EPN11
#2
EPN10
#1
EPN9
#0
EPN8
#7
3006
#6 #5 #4 #3 #2
EPS
#1
EPN
#0
EPN Workpiece number search signals are assigned to:
0 : PN1, PN2, PN4, PN8, and PN16.
1 : EPN0 to EPN13.
EPS When a program is searched using the workpiece number search function,
it is started by:
0 : Automatic operation start signal ST (when automatic operation
(memory operation) is started).
1 : Workpiece number search start signal EPNS. (Search is not started by
ST.)
NOTE
If this parameter is 1, the ST (cycle start) signal cannot be
used to start a search.
Number Message Description
059 PROGRAM NUMBER
NOT FOUND
In an external program number search
a specified program number was not
found. Otherwise, a program specified
for searching is being edited in back-
ground processing. Check the program
number and external signal. Or discon-
tinue the background eiting.
NOTE
1 This function is usable only in the memory mode; it cannot
be used in any other mode.
2 If a program that corresponds to a specified program
number has not been stored in memory, an alarm (No. 59)
is issued when a start signal (ST or EPNS) is input.
Signal address
Parameter
Alarm and Message
Note