12. DISPLAY/SET/EDIT
B–63833EN–1/02
736
3151 Axis number for the first load meter
3152 Axis number for the second load meter
3153 Axis number for the third load meter
3154 Axis number for the 4th load meter
3155 Axis number for the 5th load meter
3156 Axis number for the 6th load meter
3157 Axis number for the 7th load meter
3158 Axis number for the 8th load meter
[Data type] Byte
[Valid data range] 0, 1, . . . , the number of the control axes
Set the numbers of the axes for which measurement values on the load
meters for the eight servo motors are displayed. Set the parameters to 0 for
those axes for which a load meter need not be displayed.
2086 Rated current parameter (RTCURR)
[Data type] Word axis
4127 Load meter displayed value for maximum output
[Data type] Word axis
NOTE
The load meter display depends on servo parameter 2086
and spindle parameter 4127.
These parameters are set automatically.
OPERATOR’S MANUAL
(M series) (B–63844EN)
III.11.1.7 Operating Monitor Display
Series 0i–B
OPERATOR’S MANUAL
(T series) (B–63834EN)
III.11.1.7 Operating Monitor Display
OPERATOR’S MANUAL
(M series) (B–63864EN)
III.11.1.7 Operating Monitor Display
Series 0i Mate–B
OPERATOR’S MANUAL
(T series) (B–63854EN)
III.11.1.7 Operating Monitor Display
Note
Reference item