B–63833EN–1/02
9. SPINDLE SPEED FUNCTION
479
Refer to 9.3 “Spindle Speed Control.”
Refer to the manual for serial spindle.
The spindle loop gain multiplier corresponding to the gear currently
selected by this signal is used. When the serial spindle is used, input gear
selection signals CTH1A and CTH2A, as well.
Relationship between the selected gear and spindle gear selection signal
Analog spindle
GR2 GR1 Selected gear
0 0 1st gear
0 1 2nd gear
1 0 3rd gear
1 1 4th gear
Serial spindle
CTH1A CTH2A Selected gear
0 0 HIGH
0 1 MEDIUM HIGH
1 0 MEDIUM LOW
1 1 LOW
[Classification] Output signal
[Function] This signal indicates that the spindle orientation for the spindle
positioning has been completed.
[Output condition] When spindle orientation is complete, this signal turns to 1. When spindle
positioning is performed or cleared, it turns to 0.
#7 #6 #5 #4 #3 #2 #1 #0
G028 SPSTP *SCPF *SUCPF GR2 GR1
G070 CTH1A CTH2A
#7 #6 #5 #4 #3 #2 #1 #0
F038 SUCLP SCLP
F094 ZP4 ZP3 ZP2 ZP1
Other signals
Gear selection signal
GR1, GR2, <G028#1, #2>
Gear selection signal
CTH1A, CTH2A
<G070#3, #2>
Spindle orientation
completion signal
ZPx<F094>
Signal address