B–63833EN–1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
345
1762
Exponential acceleration/deceleration time constant for cutting feed
in the advanced preview control mode
[Data type] Word axis
[Unit of data] 1 ms
[Valid data range] 0 to 4000
Set an exponential acceleration/deceleration time constant for cutting
feed in the advanced preview control mode.
1763
Minimum speed in exponential acceleration/deceleration for cutting feed
in the advanced preview control mode
[Data type] Word axis
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 – 15000 6 – 12000
Inch machine 0.1 inch/min 6 – 6000 6 – 4800
Rotation axis 1 deg/min 6 – 15000 6 – 12000
Set a minimum speed (FL) in exponential acceleration/deceleration for
cutting feed in the advanced preview control mode.
1768
Time constant for linear acceleration/deceleration during cutting feed in
advanced preview control mode.
[Data type] Word axis
[Unit of data] ms
[Valid data range] 8 to 512
This parameter sets a time constant for linear acceleration/deceleration for
cutting feed in the advanced preview control mode.
To select an acceleration/deceleration type, use bit 6 (LS2) of parameter
No. 1602.
[Unit of data]
[Valid data range]