B–63833EN–1/02
9. SPINDLE SPEED FUNCTION
451
#7 #6 #5 #4 #3 #2 #1 #0
CONG027 *SSTP3 *SSTP2 *SSTP1 SWS3 SWS2 SWS1
G028 GR2 GR1
G029 *SSTP SOR SAR
SOV7G030 SOV6 SOV5 SOV4 SOV3 SOV2 SOV1 SOV0
R08IG032 R07I R06I R05I R04I R03I R02I R01I
SINDG033 SSIN SGN R12I R11I R10I R09I
#7 #6 #5 #4 #3 #2 #1 #0
F001 ENB
F007 SF
S07F022 S06 S05 S04 S03 S02 S01 S00
S15F023 S14 S13 S12 S11 S10 S09 S08
S23F024 S22 S21 S20 S19 S18 S17 S16
S31F025 S30 S29 S28 S27 S26 S25 S24
F034 GR3O GR2O GR1O
R08OF036 R07O R06O R05O R04O R03O R02O R01O
F037 R12O R11O R10O R09O
#7 #6 #5 #4 #3 #2 #1 #0
3705
SFA NSF
EVS
SGT SGB GST
ESF
ESF
[Data type] Bit
ESF When the spindle control function (S analog outpu or S serial output) is
used, and the constant surface speed control function is used or bit 4
(GTT) of parameter No. 3706 is set to 1:
0 : S codes and SF are output for all S commands.
1 : S codes and SF are not output for an S command in constant surface
speed control mode (G96 mode) or for an S command used to specify
maximum spindle speed clamping (G50S–––;).
NOTE
For the T series, this parametar is enabled when bit 4 (EVS)
of parameter No. 3705 is set to 1.
For the M series, SF is not output:
(1)For an S command used to specify maximum spindle
speed clamping (G92S–––;) in constant surface speed
control mode
(2)When bit 5 (NSF) of parameter No. 3705 is set to 1
Signal address
Parameter