B–63833EN–1/02
12. DISPLAY/SET/EDIT
727
6754 Accumulated cutting time
This parameter can be entered on the setting screen.
[Data type] Two–word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the accumulated cutting time that is performed
in machine feed such as linear interpolation (G01) and circular
interpolation (G02 or G03).
The actual cutting time is the sum of the values set in parameter Nos. 6753
and 6754.
6755 Accumulated time of meter drive signal (TMRON) ON
This parameter can be entered on the setting screen.
[Data type] Two–word
[Unit of data] One ms
[Valid data range] 0 to 60000
6756 Accumulated time of meter drive signal (TMRON) ON
This parameter can be entered on the setting screen.
[Data type] Two–word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter is accumulated time while input PMC signal TMRON is
on.
The actual accumulated time is the sum of the values set in parameter Nos.
6755 and 6756.
6757 Operation time (accumulated automatic operation time)
This parameter can be entered on the setting screen.
[Data type] Two–word
[Unit of data] One ms
[Valid data range] 0 to 60000