13. INPUT/OUTPUT OF DATA
B–63833EN–1/02
820
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a power mate CNC control signal. The corresponding
Power Mate side signal is IOLNK <G099#7/G251#0> (the second
address being for Power Mate–MODEL D, and the first address for all
other models).
[Classification] Output signal
[Function] This signal indicates that the Series 0i/0i Mate has started data output.
[Output condition] This signal is set to 1 in the following case:
– When data output is started
This signal is set to 0 in the following case:
– When data output is terminated
This signal is a Power Mate control signal. The corresponding power
mate CNC side signal is EXRD <G098#1/G058#1> (the second address
being for Power Mate–MODEL D, and the first address for all other
models).
[Classification] Output signal
[Function] This signal forcibly terminates power mate CNC data input/output.
[Output condition] This signal is set to 1 in the following cases:
– When the Series 0i/0i Mate issues an alarm
– When data input/output function B based on the I/O Link is used, and
external read/punch stop signal EXSTP is set to 1
This signal is set to 0 in the following case:
–When data input/output is terminated
This signal is a Power Mate control signal. The corresponding power
mate CNC side signal is EXSTP <G098#2/G058#2> (the second address
being for Power Mate–MODEL D, and the first address for all other
models).
Slave external read start
signal
ERDIO <F177#1>
Slave read/write stop
signal
ESTPIO <F177#2>