12. DISPLAY/SET/EDIT
B–63833EN–1/02
766
f Menu screen (machine maintenance only)
G10 L61 P01 [n] ;
G10 L61 P02 [n] ;
G10 L61 P03 [n] ;
:
a : Service life
r : Remaining lifetime
n : Item name
[Alphanumeric character]
q : Count type
0 = No counting.
1 = Nonstop counting.
2 = Counting continues as long as the power is on.
3 = Counting continues throughout run time.
4 = Counting continues throughout cutting time.
In EDIT mode, pressing the [READ] soft key causes input data to be
registered according to a specified format (G10). Registration is possible
even if the format (G10) is already in program memory as long as the
programmable data input option is available.
NOTE
Registration may not be performed correctly unless the
input format (G10) matches the output format.
8911 Lifetime versas service life parcentage
[Data type] Byte
[Unit of data] 1%
[Valid data range] 0 to 100
On the periodic maintenance screen, the remaining lifetime display turns
red for warning purposes, if the remaining lifetime goes below a specified
percentage of the corresponding service life.
Format
D Data input
Parameter