B–63833EN–1/02
15. PMC CONTROL FUNCTION
895
The continuous feed command (EC0g to EC6g: 06h) and external pulse
synchronization command (EC0g to EC6g: 0Bh, 0Dh to 0Fh) can be
terminated by setting reset signal ECLRg to “1”. When these commands
are terminated, the servo motor decelerates and stops, the axis moving
signal EGENg is set to “0”, and the control axis selection status signal
*EAXSL is set to “0”. Confirm that the control axis selection status signal
*EAXSL has been set to “0” before issuing the next command. Do not
set reset signal ECLRg to “0” until the control axis selection status signal
*EAXSL has been set to “0”.
The speed command (EC0g to EC6g: 10h) can also be terminated by
setting the reset signal ECLRg to “1”. When this command is terminated,
the servo motor decelerates and stops, and the axis moving signal EGENg
is set to “0”. Confirm that the axis moving signal EGENg has been set
to “0” before issuing the next command. Do not attempt to set the reset
signal ECLRg to “0” until the axis moving signal EGENg has been set to
“0”.
[Classification] Input signal
[Function] When this signal is set to “1”, the following is performed:
(1) When the tool is moving along the axis: Decelerates and stops the
tool.
(2) When the tool is in dwell: Stops the operation.
(3) When an auxiliary function is being executed: Stops the operation
when auxiliary function completion signal EFINg is input.
The stopped operation can be restarted by setting this signal to “0”.
[Classification] Input signal
[Function] When block stop signal ESBKg is set to “1” during the execution of a
command issued from the PMC, axis control is stopped after the block
being executed is completed. When this signal is set to “0”, the buffered
command is executed. Block stop signal ESBKg is disabled when block
stop disable signal EMSBKg is set to “1” for the block.
8 Axis control
temporary stop signal
ESTPg
9 Block stop signal
ESBKg
10 Block stop disable
signal EMSBKg