6.MNEMONIC EDITING B-66234EN/05
- 256 -
The parameters for each model are described below.
(1) For PMC-PA3/SA3/SA5/SB4/SB5/SB6
%@0
2 BINARY
3 NO
4 PMC-RB5
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
(BINARY or BCD)
(Presence: YES, Absence: NO)
(PMC-PA3/PMC-RA3/PMC-RA5/PMC-
RB4/PMC-RB5/PMC-RB6)
(2) For PMC-SB3/NB6
%@0
2 BINARY
3 NO
4 PMC-NB6
7 100
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
7: Ladder execution time
(BINARY or BCD)
(Presence: YES, Absence: NO)
(PMC-RB3/PMC-NB6)
(fixed at 100%)
(3) For PMC-SC3/SC4
%@0
2 BINARY
3 NO
4 PMC-RC3
5 000000
6 50
7 100
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
5: Head address of language program link
control statement data
6: Time ratio to execute language program
7: Ladder execution time
(BINARY or BCD)
(Presence: YES, Absence: NO)
(PMC-RC3/PMC-RC4)
(0 or 800000 to 8FFFFF(hex))
(1 to 99%)
(fixed at 100%)
(4) For PMC-NB/NB2
%@0
2 BINARY
3 NO
4 PMC-NB
5 000000
6 50
7 100
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
5: Head address of language program link
control statement data
6: Time ratio to execute language program
7: Ladder execution time
(BINARY or BCD)
(Presence: YES, Absence: NO)
(PMC-NB/PMC-NB2)
(0 or 200000 to 2FFFFF(hex))
(1 to 99%)
(fixed at 100%)
(5) For PMC-SB7
%@0
2 BINARY
3 NO
4 PMC-SB7
7 150
11 UNUSE
12 0
13 UNUSE
14 0
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
7: Ladder execution time
11: I/O link assignment selection function
12: Number of basic I/O link groups
13: I/O link assignment selection function
14: Number of basic I/O link groups
(BINARY or BCD)
(Presence: YES, Absence: NO)
(PMC-SB7)
(Used: USE, Not used: UNUSE) (channel 1)
(0 to 16) (channel 1)
(Used: USE, Not used: UNUSE) (channel 2)
(0 to 16) (channel 2)