FANUC LADDER-III
SUPPLEMENTARY OPERATOR’S MANUAL
01 05/01/14 First issue B-66234EN/05-1
EDIT
DATE
DESIG.
DESCRIPTION
69/69
TITLE
DRAW.NO.
SHEET
CUST.
9.3.7.6 File format and display of extra relay (E)
The file format of extra relay (E) is decided by the setting of the following keep relays.
Table 9.3.7.6(a) Parameter output of extra relay
Output E address (K906.3)
0 (Yest) 1 (No)
0
(No)
Contents of each byte None
Enable E address control
data (K906.7)
1
(Yes)
Contents according to the control
data
None
[Format with control data]
N635000 Pnn;
Total of extra relay group (1-100)
N635002 Pnnnnnnnn; Table parameter of group 1 data (bit type)
N635003 Pn; Group 1 data type (0,1,2,3)
N635004 Pnnnn; Data number in group of group 1 (1-xxxxx)
N635006 Pnnnn; Data first address in group of group 1(0~nnnnn)
The value of extra relay is output to N690000 or later.
Output address and value follow the control data of extra relay (E).
As for detail format of the PMC parameter, please refer to the format of the PMC parameter
2.3.2 of programming manuals (B-63983EN/02).
The display of extra relay screen is decided by the setting of the following keep relays.
Table 9.3.7.6(b) Display of extra relay screen
Don’t display the control data screen of the data table (K900.7).
0(Display the control data) 1 (Don’t display the control data)
0(No)
Don’t display extra relay screen Don’t display extra screen.
Enable extra relay screen
(K909.5).
1(Yes)
Display extra relay screen
Display the control data of extra
relay
Display extra relay screen
Don’t display the control data of
extra relay