B-66234EN/05 6.MNEMONIC EDITING
- 257 -
(6) For 30i-A PMC (1st PMC)
%@0
2 BINARY
3 NO
4 30i-A PMC
31 1
32 -1
33 0
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
31: Number of display language (comment)
32: CNC display language number 1
33: Comment set number 1
(BINARY or BCD)
(Presence: YES, Absence: NO)
(30i-A PMC)
(1-16)
(-1, 0-127)
(0-16)
(7) For 30i-A PMC (2nd PMC)
%@0
2 BINARY
3 NO
4 30i-A PMC(2nd)
31 1
32 -1
33 0
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
31: Number of display language (comment)
32: CNC display language number 1
33: Comment set number 1
(BINARY or BCD)
(Presence: YES, Absence: NO)
(30i-A PMC(2nd))
(1-16)
(-1, 0-127)
(0-16)
(8) For 30i-A PMC (3rd PMC)
%@0
2 BINARY
3 NO
4 30i-A PMC(3rd)
31 1
32 -1
33 0
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
31: Number of display language (comment)
32: CNC display language number 1
33: Comment set number 1
(BINARY or BCD)
(Presence: YES, Absence: NO)
(30i-A PMC(3rd))
(1-16)
(-1, 0-127)
(0-16)
(9) For 30i-A PMC (Dual check safety)
%@0
2 BINARY
3 NO
4 30i-A PMC(DCS)
31 1
32 -1
33 0
%
2: Counter data type
3: Presence or absence of operator panel
4: PMC type
31: Number of display language (comment)
32: CNC display language number 1
33: Comment set number 1
(BINARY or BCD)
(Presence: YES, Absence: NO)
(30i-A PMC(DCS))
(1-16)
(-1, 0-127)
(0-16)
NOTE
Please refer to Subsection 3.10.1 “Operation” of
Section 3.10 “EDITING SYSTEM PARAMETERS”
for the detail.