APPENDIX 1 REQUIRED NC SETTING FOR EACH BASIC OPERATION PACKAGE 1 SCREEN B-62994EN/02
-414-
Position error 1
Changed by the "Operation Mode".
Contents Condition
Not displayed "Speed Control" mode
Position error S1 "Sync. Control" mode
Position error S Except the above-mentioned types of "Operation Mode"
Position error 2
Changed by the "Operation Mode".
Contents Condition
Position error Z "Rigid Tapping" mode
Position error S2 "Sync. Control" mode
Not displayed Except the above-mentioned types of "Operation Mode"
Sync. error
Displayed only when the "Operation Mode" is "Sync. Control" or "Rigid Tapping".
Spindle Setting Parameter
Changed by the selected spindle.
Contents Condition
Gear ratio Basic
Max. motor speed Basic
Max. C axis speed First spindle
Max. spindle speed First spindle
39 [Waveform Diagnosis setting] [Waveform Diagnosis graph] Screen
FS16/18/21/NC Board :
Supported NC FS16/160-MB/TB/MMB/TTB, FS16/160-MC/TC/MMC/TTC, FS16i/160i-MA/TA
FS18/180-MB/TB/TTB, FS18/180-MC/TC/TTC, FS18i/180i-MA/TA
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
Parameter 3112#0 = 0 Do not display Waveform Diagnosis Screen.
= 1 Display Waveform Diagnosis Screen.
FS15:
Supported NC FS15 Model-B M/T/TT
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
None
Power Mate:
This function is not supported on the Power Mate.