B-63943EN-1/02 1.AXIS CONTROL
- 97 -
Parameter
14985
Number of the farthest second cyclical pitch error compensation point in the
negative direction for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1023
The compensation point specified with this parameter is used as a
reference point for second cyclical pitch error compensation. This
reference point is used as a compensation point at the reference
position. The compensation value at the compensation reference point
must be 0.
14986
Number of the farthest second cyclical pitch error compensation point in the
positive direction for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1023
Set the number of the farthest second cyclical pitch error
compensation point in the positive direction for each axis.
14987
Interval between second cyclical pitch error compensation points for each
axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] From 0 to the space between neiboring points of the pitch error
compensation (parameter No. 3624).
Set the interval between second cyclical pitch error compensation
points for each axis.