16.MEASUREMENT B-63943EN-1/02
- 1860 -
16.3.5 Torque Limit Skip Function
Overview
When the movement command following G31 P99 (or G31 P98) is
executed with the servo motor torque limit
*1
overridden, cutting feed
similar to linear interpolation (G01) can be performed. When the servo
motor torque reaches the torque limit (overridden servo motor torque
limit) by pushing or the skip signal (including the high-speed skip
signal) is input during the movement, the remaining movement
commands are canceled and then the next block is executed. (The
operation that executes the next block by canceling the remaining
movement command is called skip operation later.)
The servo motor torque limit can be overridden by:
(1) Executing the torque limit override command for the PMC
window.
(2) Executing the address Q command in the same block in which
G31 P99 (or G31 P98) exists.
*1
: The servo motor torque limit is automatically set according to the
settings of the motor model.
Signal
Torque limit reached signals TRQL1
#n+1
to TRQL4
#n+1
<Fn114>
[Classification] Input signal
[Function] Indicates that the torque limit has been reached.
[Output condition] Set to "1" when:
- The torque limit has been reached.
Set to "0" when:
- The torque limit has not been reached.
Indicates the signal for each axis. The value at the end of a signal
name indicates the number of each control axis.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Fn114
TRQL4
#1
TRQL3
#1
TRQL2
#1
TRQL1
#1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1803 TQA TQI
[Input type] Parameter input
[Data type] Bit path
# 0 TQI Within a torque limit, an in-position check is:
0: Made.
1: Not made.
# 1 TQA Within a torque limit, an excessive stop-time/move-time error is:
0: Checked.
1: Not checked.