4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 546 -
4.10 REFERENCE POSITION SIGNAL OUTPUT FUNCTION
Overview
If, after the establishment of the reference position on each axis, the
coordinates in the machine coordinate system match the reference
position, this function outputs a signal as the DO signal (Fn517) of the
PMC.
Also, if the coordinates in the machine coordinate system matches the
second reference position, the function outputs a signal as the DO
signal (Fn518) of the PMC.
Signal
Reference position match signals RP11 to RP18<Fn517>
[Classification] Output signal
[Function] Reports that the coordinates in the machine coordinate system matches
the reference position.
There is an independent one for each axis, with the last digit
indicating the number of the corresponding controlled axis.
RP1x
x : 1 The machine coordinates on the first axis match the
reference position.
2 The machine coordinates on the second axis match the
reference position.
3 The machine coordinates on the third axis match the
reference position.
: :
: :
[Output condition] This signal becomes "1" only when, after the establishment of the
reference position on each axis, the coordinates in the machine
coordinate system match the reference position.
NOTE
This signal does not take the delay due to
acceleration/deceleration into consideration.
No in-position check is performed.
Second reference position match signals RP21 to RP28<Fn518>
[Classification] Output signal
[Function] Reports that the coordinates in the machine coordinate system matches
the second reference position.
There is an independent one for each axis, with the last digit
indicating the number of the corresponding controlled axis.
RP2x
x : 1 The machine coordinates on the first axis match the second
reference position.
2 The machine coordinates on the second axis match the
second reference position.