1.AXIS CONTROL B-63943EN-1/02
- 28 -
Mirror image check signals MMI1 to MMI8<Fn108>
[Classification] Output signal
[Function] These signals indicate the mirror image condition of each axis.
The mirror image is set by taking the logical sum of the signal from
the MDI panel and the input signal of the machine tool, then relaying
the information to the machine tool.
These signals are provided for every control axis; the numeral in the
signal name indicates the relevant control axis number.
MMIx
x : 1 ..... Mirror image is applied to the 1st axis
2 ..... Mirror image is applied to the 2nd axis
3 ..... Mirror image is applied to the 3rd axis
: :
: :
[Output condition] These signals turn to "1" when:
- Mirror image signal MIn of the corresponding axis is "1"; or
- Mirror image of the corresponding axis is turned on by setting
data from the MDI panel.
These signals turn to "0" when:
- Mirror image signal (MIn) of the corresponding axis is "0" and
the setting of the mirror image in the control unit is turned off.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn106 MI8 MI7 MI6 MI5 MI4 MI3 MI2 MI1
#7 #6 #5 #4 #3 #2 #1 #0
Fn108 MMI8 MMI7 MMI6 MMI5 MMI4 MMI3 MMI2 MMI1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
0012 MIRx
[Input type] Setting input
[Data type] Bit axis
# 0 MIRx Mirror image for each axis
0: Mirror image is off. (Normal)
1: Mirror image is on. (Mirror)
Warning
WARNING
1 When programmable mirror image (machining
center system) and ordinary mirror image are
specified at the same time, programmable mirror
image is applied first.
2 No programmable mirror image (machining center
system) affects mirror image check signals MMI1 to
MMI8 <F108>.