4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 474 -
1250
Coordinate system of the reference position used when automatic
coordinate system setting is performed
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate system of the reference position on each axis to be
used for setting a coordinate system automatically.
#7 #6 #5 #4 #3 #2 #1 #0
1401 JZR RPD
[Input type] Parameter input
[Data type] Bit path
# 0 RPD Manual rapid traverse during the period from power-on time to the
completion of the reference position return.
0: Disabled (Jog feed is performed.)
1: Enabled
# 2 JZR The manual reference position return at JOG feedrate
0: Not performed
1: Performed
1420 Rapid traverse rate for each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set the rapid traverse rate when the rapid traverse override is 100% for
each axis.