1.AXIS CONTROL B-63943EN-1/02
- 230 -
Input signal
Signal name Address Classification Remarks
Feed axis direction
selection signal
+Jx
-Jx
G100
G102
Cartesian A movement is made in the Cartesian coordinate
system. (When the +J/-J signal for the angular
axis is made high, a movement is made also along
the perpendicular axis.)
Mirror image MIx G106 Slanted Mirror image is applied to the slanted coordinate
system for each axis independently.
Caution)
Be sure to turn off the mirror image signal for the
angular axis and perpendicular axis engaged in
manual operation.
Axis-by-axis machine
lock
MLKx G108 Slanted This signal is applied to each axis independently.
Output signal
Signal name Address Classification Remarks
In-position signal INPx F104 Slanted Applied to each axis independently.
Mirror image check
signal
MMIx F108 Slanted Applied to each axis independently.
Controlled axis
removal in-progress
signal
MDTCHx F110 Slanted Applied to each axis independently.
Travel in-progress
signal
MVx F102 Slanted Applied to each axis independently.
Reference position
return completion
signal
ZPx F094 Cartesian Applied to each axis independently. (A manual
reference position return operation and the first
automatic reference position return operation after
power-up need to be performed first for the
angular axis.)
2nd reference position
return completion
signal
ZP2x F096 Cartesian Applied to each axis independently.
3rd reference position
return completion
signal
ZP3x F098 Cartesian Applied to each axis independently.
4th reference position
return completion
signal
ZP4x F100 Cartesian Applied to each axis independently.
Limitation
- Three-dimensional coordinate conversion
If the basic three axes in the three-dimensional coordinate conversion
mode do no include a perpendicular axis and angular axis for angular
axis control, operation cannot be performed normally in a correct
slanted coordinate system.
- Linear scale with an absolute address reference mark
• For both of the angular axis and perpendicular axis, a linear scale
with an absolute address reference mark must be used.
• Reference position return operation must be first completed along
the angular axis.