B-63943EN-1/02-01
Edit
Apprv.
Design
Sheet
Title
Draw
No.
61/126
Date
Design
Descri
tion
Date
FANUC Se
ies 30i/31i/32i-
, 31i-
5
PMC Axis Control
2004.10.7
* Can also be set to the rapid traverse rate with the parameter RDE (No. 8001#3).
(31) Override 0% signal EOV0 <F129.5>
[Classification] Output signal, path-by-path signal
[Function] Indicates whether the override value is 0%.
[Operation] This signal is set to "1" when the feedrate override is 0%.
(32) Skip signal ESKIP <X004.6>, ESKIP#2 <X013.6>, ESKIP#3<X011.6>
[Classification] Direct input signal, path-by-path signal
[Function] Applies skip.
[Operation] When this signal is set to "1" during execution of the skip cutting command, the
block being executed is immediately stopped and the next block is executed. This
signal is unique during PMC axis control. Parameter SKE (No. 8001#7) can be
used to select whether to use signal SKIP, which is the common skip signal for the
PMC and CNC, or PMC-specific skip signal ESKIP.
This skip signal is valid for those axes that are assigned to path 1 to path 3.
For those axes that are assigned to path 1, ESKIP (X004.6) is valid.
For those axes that are assigned to path 2, ESKIP#2 (X013.6) is valid.
For those axes that are assigned to path 3, ESKIP#3 (X011.6) is valid.
This skip signal cannot be used for those axes that are assigned to path 4 to path 10.
(33) Distribution completion signals EADEN1 to EADEN32 <F112>
[Classification] Output signal, axis-by-axis signal)
[Function] Indicates the state of distribution based on PMC axis control.
[Operation] These signals are set to "0" when the tool is moving with a command from the PMC.
The signals are set to "1" when the tool is not moving, except when it is stopped by
an axis control temporary stop signal ESTPg during the execution of a move
command.
(34) Buffer full signal EABUFg <F131.1, F134.1, F137.1, F140.1>
[Classification] Output signal, group-by-group signal
[Function] Indicates the PMC axis control command buffering state.
[Operation] When the group input buffer holds a command block, this signal is set to 1. When
no command is buffered, this signal is set to 0.
(35) Controlling signals EACNT1 to EACNT32 <F182>
[Classification] Output signal, axis-by-axis signal)
[Function] Indicates that PMC axis control is being exercised.
[Operation] When the control axis selection status signal *EAXSL is set to 1, the bit signal
corresponding to an axis being controlled is set to 1.
A bit signal is set to 1 also when the servo-off signal ESOFg is set to 1.