12.TOOL FUNCTIONS B-63943EN-1/02
- 1608 -
#7 #6 #5 #4 #3 #2 #1 #0
13200 NFD NAM T0O TP2 ETE TRT THN TCF
[Input type] Parameter input
[Data type] Bit path
# 0 TCF When a T code is specified with the tool management function:
0: A cartridge number and pot number found by the NC are output.
1: The specified T code is output without modification.
# 1 THN When NX.T and HD.T are displayed with the tool management
function:
0: The tool type numbers at the first spindle position and the first
standby position are displayed.
1: The values specified from the PMC window are displayed.
# 2 TRT As the remaining lifetime value for outputting the tool life arrival
notice signal:
0: The remaining lifetime of the last tool is used.
1: The sum of the remaining lifetimes of the tools with the same
type number is used.
NOTE
This parameter is valid when bit 3 (ETE) of
parameter No. 13200 is set to 0 (arrival notice for
each type number).
# 3 ETE The tool life arrival notice signal is output:
0: For each tool type.
1: For each tool.
# 4 TP2 The punch-out format of cartridge management data is:
0: New registration format (G10L76P1 format).
1: Modification format (G10L76P2 format).
# 5 T0O When T0 is specified:
0: A tool search is made assuming that the tool type number is 0.
1: The cartridge number and pot number are assumed to be 0.
# 6 NAM When a T code is specified, but a valid tool with a remaining lifetime
cannot be found:
0: The alarm (PS5317) "LIVES OF ALL TOOLS EXPIRED" is
issued.
1: The alarm is not issued. Instead, the tool with the maximum
tool management number is selected from the tools of the
specified tool type, and TMFNFD<F315#6> is set to 1.