B-63943EN-1/02 5.AUTOMATIC OPERATION
- 589 -
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn062 RTNT
#7 #6 #5 #4 #3 #2 #1 #0
Fn066 RTPT
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
5200 DOV
[Input type] Parameter input
[Data type] Bit path
# 4 DOV Override during extraction in rigid tapping
0: Invalidated
1: Validated (The override value is set in parameter No.5211.
However, set an override value for rigid tapping return in
parameter No. 5381.)
5381 Override value during rigid tapping return
[Input type] Parameter input
[Data type] Word path
[Unit of data] %
[Valid data range] 0 to 200
This parameter is used to set the override value during rigid tapping
return.
If the setting is 0, no override is applied.
NOTE
This parameter is valid when bit 4 (DOV) of
parameter No. 5200 for enabling override at normal
extraction time is set to 1.
5382 Amount of return for rigid tapping return
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the drilling axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B) )
(When the increment system is IS-B, 0.0 to +999999.999)
This parameter is used to set an extra amount of rigid tapping return.
The tool is retracted additionally near point R by the distance set in
this parameter. If the tool has already been retracted from rigid
tapping, it will be retracted further only by the distance specified in
this parameter.