1.AXIS CONTROL B-63943EN-1/02
- 204 -
8330
Multiplier for a maximum allowable synchronization error immediately after
power-up
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word path
[Valid data range] 1 to 100
Until synchronization establishment is completed immediately after
power-up, synchronization error excessive alarm 2 is checked using
the maximum allowable error (parameter No. 8332) multiplied by the
value set in this parameter.
If the result produced by multiplying the value of parameter No. 8332
by the value of this parameter exceeds 32767, the value is clamped to
32767.
8331
Maximum allowable synchronization error for synchronization error
excessive alarm 1
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter sets a maximum allowable synchronization error for
synchronization error excessive alarm 1.
Set this parameter with a slave axis.
8332
Maximum allowable synchronization error for synchronization error
excessive alarm 2
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter sets a maximum allowable synchronization error for
synchronization error excessive alarm 2.
Set this parameter with a slave axis.