B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1275 -
5207 Clamp/unclamp sequence status
The clamp/unclamp sequence status is indicated. (For each
controlled axis)
1) Sequence for switching to the spindle positioning mode
Indication Description
00030001 Wait until SPSTPs is turned on (0->1)
00030002 Wait for completion of switching to spindle
positioning mode
00030004 Wait until *SUCPFs is turned on (1->0)
00030005 Wait for completion of orientation operation
00030006 Wait until *SCLPFs is turned on (1->0)
2) Spindle positioning sequence
Indication Description
00070001 Wait until SPSTPs is turned on (0->1)
00070002 Wait until *SUCPFs is turned on (1->0)
00070003 Wait for completion of positioning operation
00070004 Wait until *SCLPFs is turned on (1->0)
For spindle positioning sequence B specifications (when bit 7
(IMB) of parameter No. 4950 is set to 1)
000D0001 Wait until SPSTPs is turned on (0->1)
000D0002 Wait for completion of switching to spindle
positioning mode
000D0004 Wait until *SUCPFs is turned on (1->0)
000D0005 Wait for completion of positioning operation
000D0006 Wait until *SCLPFs is turned on (1->0)
000D0007 Wait for completion of spindle positioning mode
cancellation
3) Spindle positioning mode cancellation sequence
Indication Description
000B0001 Wait until SPSTPs is turned on (0->1)
000B0002 Wait until *SUCPFs is turned on (1->0)
000B0004 Wait for completion of spindle positioning mode
cancellation
FFFFFFFF End of sequence
Spindle screen
In the spindle positioning mode, indications related to the spindle
positioning mode appear.