B-63943EN-1/02 16.MEASUREMENT
- 1855 -
#7 #6 #5 #4 #3 #2 #1 #0
6200 SKF SLS SK0 GSK
[Input type] Parameter input
[Data type] Bit path
# 0 GSK As a skip signal, the skip signal SKIPP is:
0: Invalid.
1: Valid.
# 1 SK0 This parameter specifies whether the skip signal is made valid under
the state of the skip signal SKIP and the multistage skip signals SKIP2
to SKIP8.
0: Skip signal is valid when these signals are 1.
1: Skip signal is valid when these signals are 0.
# 5 SLS
0: The multi-step skip function does not use high-speed skip signals
while skip signals are input. (The conventional skip signal is
used.)
1: The multi-step skip function uses high-speed skip signals while
skip signals are input.
NOTE
Skip signals (SKIP, SKIP to SKIP8) are enabled
regardless of this parameter. These signals can be
disabled by setting the parameter IGX (No.
6201#4).
# 7 SKF Dry run, override, and automatic acceleration/deceleration for G31
skip command
0: Disabled
1: Enabled
#7 #6 #5 #4 #3 #2 #1 #0
6201 SKPXE IGX SEB
[Input type] Parameter input
[Data type] Bit path
# 1 SEB If the skip function is used, the positional deviation and the number of
accumulated pulses due to acceleration/deceleration at the time when
the skip signal is turned on are:
0: Not considered.
1: Considered for compensation.
The position where the skip signal is input is found by considering the
positional deviation and the number of accumulated pulses due to
actual acceleration/deceleration at the time when the skip signal is
turned on.