B-63943EN-1/02 4.REFERENCE POSITION ESTABLISHMENT
- 523 -
Number Message Description
DS0027 MISMATCH OF SYNCHRONOUS
AXIS(D.C.S)
Master/slave axes of feed axis synchronization control,
one of them is the linear scale with distance-coded
reference marks, and the other of them is not the linear
scale with distance-coded reference marks.
Please establish reference position with the input signal
SYNCn<G138>, SYNCJn<G140> or parameter setting
to 0.
DS1448 ILLEGAL PARAMETER (D.C.S.) The setting value of parameter for reference marks is
satisfied the following any conditions.
- The absolute-position detection function is enabled.
- Either parameter 1821 (mark-1 interval) or parameter
1882 (mark-2 interval) is set to 0.
- Parameters 1821 and 1882 have identical settings.
- The difference between the settings made for
parameters 1821 and 1882 is greater than or equal to
twice either setting.
- The setting value of parameters 1883 and 1884 are
over the valid data range.
DS1449 REFERENCE MARK ARE DIFFERENT
FROM PARAMETER
In case of distance coded linear scale I/F, the actual
interval of reference marks is different from parameter
(No.1821,1882) setting value.
Diagnosis display
3545 Measurement point 1 of the reference marks of distance coded linear scale
3546 Measurement point 2 of the reference marks of distance coded linear scale
3547 Measurement point 3 of the reference marks of distance coded linear scale
3548 Measurement point 4 of the reference marks of distance coded linear scale
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -999999999 to 999999999
3549 Internal status of the reference marks of distance coded linear scale
3550 Scale counter value of the reference marks of distance coded linear scale
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -999999999 to 999999999