B-63943EN-1/02 1.AXIS CONTROL
- 147 -
14444
ATR value corresponding to connector 1 on the first separate detector
interface unit connected to an additional axis board
14445
ATR value corresponding to connector 2 on the first separate detector
interface unit connected to an additional axis board
to
14451
ATR value corresponding to connector 8 on the first separate detector
interface unit connected to an additional axis board
14452
ATR value corresponding to connector 1 on the second separate detector
interface unit connected to an additional axis board
to
14459
ATR value corresponding to connector 8 on the second separate detector
interface unit connected to an additional axis board
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 32
Each of these parameters sets the value (ATR value) of the address
translation table corresponding to each connector on a separate
detector interface unit connected to an additional axis board.
To an additional axis board, the first and second separate detector
interface units are connected.
In each of these parameters, set a value obtained by subtracting 25
from the setting of parameter No. 1023 for the axis connected to a
connector on a separate detector interface unit.
When there is an axis for which bit 1 of parameter No. 1815 is set to 0
to use a separate detector interface unit, set 32 for those connectors
that are not used.
NOTE
1 Set these parameters when using an additional
axis board.
2 When the FSSB is set to the automatic setting
mode (when the parameter FMD (No.1902#0) is
set to 0), parameter Nos. 14444 to 14459 are
automatically set as data is input on the FSSB
setting screen. When the manual setting 2 mode is
set (when the parameter FMD (No.1902#0) is set
to 1), be sure to directly set values in parameter
Nos. 14444 to 14459.