1.AXIS CONTROL B-63943EN-1/02
- 134 -
(2) Axis setting screen
On the axis setting screen, the following items can be specified:
• M1:Connector number for separate detector interface unit 1
• M2:Connector number for separate detector interface unit 2
• M3:Connector number for separate detector interface unit 3
• M4:Connector number for separate detector interface unit 4
For an axis that uses each separate detector interface unit,
enter a connector number using a number 1 to 8 (maximum
number of connectors on a separate detector interface unit).
When a separate detector interface unit is not used, enter
“0”.
When a separate detector interface unit is not connected and
a number outside the valid range is entered, the warning
message ILLEGAL DATA is displayed. When a separate
detector interface unit is connected and a number outside
the valid range is entered, the warning message DATA IS
OUT OF RANGE is displayed.
• 1-DSP
Enter the number of servo HRV3 and HRV4 controlled axes
that can be controlled by one DSP when that number is
limited.
For servo HRV3 controlled axes Setting: 3
For servo HRV4 controlled axes Setting: 1
The same value is set for axes other than Cs contour
controlled axes.
If a number other than 0, 1, or 3 is entered, the message
FORMAT ERROR is displayed.
• CS : Cs contour controlled axis
Enter spindle number (1 to 8) for the Cs contour controlled
axis. If a number other than 0 to 8 is entered, the message
DATA IS OUT OF RANGE is displayed.
• TNDM
Enter odd and even numbers for axes for tandem control or