B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1293 -
1820 Command multiplier for each axis (CMR)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 1 to 96
Set 2 for spindle positioning.
1821 Reference counter size for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
Set a reference counter size.
As a reference counter size, specify a grid interval for reference
position return based on the grid method.
When a value less than 0 is set, the specification of 10000 is assumed.
1826 In-position width for each axis
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
The in-position width is set for each axis.
When the deviation of the machine position from the specified
position (the absolute value of the positioning deviation) is smaller
than the in-position width, the machine is assumed to have reached the
specified position. (The machine is in the in-position state.)
1827 In-position width in cutting feed for each axis
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Set an in-position width for each axis in cutting feed. This parameter
is used when bit 4 (CCI) of parameter No.1801=1.