B-63943EN-1/02 8.MULTI-PATH CONTROL
- 895 -
#7 #6 #5 #4 #3 #2 #1 #0
8162 MUMx MCDx MPSx MPMx PKUx SERx SMRx
[Input type] Parameter input
[Data type] Bit axis
# 0 SMRx Synchronous mirror-image control is:
0: Not applied. (The master and slave axes move in the same
direction.)
1: Applied. (The master and slave axes move in opposite
directions.)
# 1 SERx The synchronization deviation is:
0: Not detected.
1: Detected.
NOTE
When both master and slave axes move in
synchronization, the positioning deviations of the
corresponding axes are compared with each other.
If the difference is greater than or equal to the
value specified in parameter No.8181, an alarm
occurs. When either axis is in the parking or
machine-locked state, however, the
synchronization deviation is not detected. If the
master axis and slave axis are in the same path,
synchronization deviation detection cannot be
performed.
# 2 PKUx In the parking state,
0: The absolute, relative, and machine coordinates are not updated.
1: The absolute and relative coordinates are updated. The machine
coordinates are not updated.
NOTE
1 With an axis for which polar coordinate interpolation
is specified, set this parameter to 1. If this
parameter is set to 0, a coordinate shift can occur
when a single block stop or feed hold is performed in
the polar coordinate interpolation mode.
2 With an axis that is set to function as a synchronous
master axis and synchronous slave axis at the same
time (with parameter SYWx (No. 8167#1)), set this
parameter to 1.
3 With an axis specified in the three-dimensional
coordinate conversion mode, set this parameter to 1.
If this parameter is set to 0, the alarm (PS0367) is
issued.