B-63943EN-1/02 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 765 -
3241 Character blinking in the AI contour control I mode (first character)
to
3247 Character blinking in the AI contour control I mode (seventh character)
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 95
Set the first to seventh blinking characters in the AI contour control I
mode by using ASCII codes represented as decimal numbers.
When 0 is set in all of these parameters, "AICC I" blinks.
Code numbers 032 to 095 in the "character-code correspondence
table" can be set.
3251 Character blinking in the AI contour control II mode (first character)
to
3257 Character blinking in the AI contour control II mode (seventh character)
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 95
Set the first to seventh blinking characters in the AI contour control II
mode by using ASCII codes represented as decimal numbers.
When 0 is set in all of these parameters, "AICC II" blinks.
Code numbers 032 to 095 in the "character-code correspondence
table" can be set.
#7 #6 #5 #4 #3 #2 #1 #0
7055 BCG
[Input type] Parameter input
[Data type] Bit path
# 3 BCG The bell-shaped acceleration/deceleration time constant change
function is:
0: Disabled.
1: Enabled.
7066
Acceleration/deceleration reference speed for the bell-shaped
acceleration/deceleration time constant change function
[Input type] Setting input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
This parameter is used when the pre-interpolation bell-shaped
acceleration/deceleration time constant change function is used.