16.MEASUREMENT B-63943EN-1/02
- 1844 -
#7 #6 #5 #4 #3 #2 #1 #0
6200 SKF SRE HSS SK0 GSK
[Input type] Parameter input
[Data type] Bit path
# 0 GSK As a skip signal, the skip signal SKIPP is:
0: Invalid.
1: Valid.
# 1 SK0 This parameter specifies whether the skip signal is made valid under
the state of the skip signal SKIP and the multistage skip signals SKIP2
to SKIP8.
0: Skip signal is valid when these signals are 1.
1: Skip signal is valid when these signals are 0.
# 4 HSS
0: The skip function does not use high-speed skip signals while skip
signals are input. (The conventional skip signal is used.)
1: The step skip function uses high-speed skip signals while skip
signals are input.
# 7 SKF Dry run, override, and automatic acceleration/deceleration for G31
skip command
0: Disabled
1: Enabled
#7 #6 #5 #4 #3 #2 #1 #0
6201 SKPXE IGX SEB
[Input type] Parameter input
[Data type] Bit path
# 1 SEB If the skip function is used, the positional deviation and the number of
accumulated pulses due to acceleration/deceleration at the time when
the skip signal is turned on are:
0: Not considered.
1: Considered for compensation.
The position where the skip signal is input is found by considering the
positional deviation and the number of accumulated pulses due to
actual acceleration/deceleration at the time when the skip signal is
turned on.
# 4 IGX When the high-speed skip function is used, SKIP, SKIPP, and SKIP2
to SKIP8 are:
0: Enabled as skip signals.
1: Disabled as skip signals.