1.AXIS CONTROL B-63943EN-1/02
- 156 -
Parameter
1240 Coordinate value of the reference position in the machine coordinate system
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate values of the reference position in the machine
coordinate system.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Machine coordinate system