4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 494 -
No. 1401) can be used to specify whether nonlinear interpolation
positioning or linear interpolation positioning is used for the tool path
from the reference position to the intermediate point and the tool path
from the intermediate point to the specified position.
NOTE
As with the positioning command (G00), positioning
in the absolute coordinate system is used for
traversing from the reference position to the
intermediate point or traversing from the intermediate
point to the specified point.
Therefore, the tool path is specified by LRP (bit 1 of
parameter No. 1401).
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1002 AZR
[Input type] Parameter input
[Data type] Bit path
# 3 AZR When no reference position is set, the G28 command causes:
0: Reference position return using deceleration dogs (as during
manual reference position return) to be executed.
1: P/S alarm No.090 to be issued.
NOTE
When reference position return without dogs is
specified, (when bit 1 (DLZ) of parameter No.1002 is
set to 1 or bit 1 (DLZx) of parameter No.1005 is set
to 1) the G28 command specified before a reference
position is set causes an alarm PS0304 to be issued,
regardless of the setting of AZR.
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 5 ZMIx The direction of manual reference position return is:
0: + direction
1: - direction