17.PMC CONTROL FUNCTION B-63943EN-1/02
- 2034 -
17.3 EXTENDED EXTERNAL MACHINE ZERO POINT SHIFT
Overview
The conventional external machine zero point shift value function
cannot make shifts on multiple axes simultaneously.
With this extended function, external machine zero point shifts can be
performed on all controlled axes. An external machine zero point
shift value is to be set in a parameter-set R area. A shift value must
be specified using a binary code, and the absolute value of a number
from -32767 to 32767 must be specified.
Explanation
- Setting
This function is enabled by setting bit 0 (EMS) of parameter No. 1203
to 1. Enter a desired external machine zero point shift value at the
location starting at the address (R area of the PMC) set in parameter
No. 1280.
If 100 is set in parameter No. 1280, enter shift values at the location
starting at R100 of the PMC. Set an even number in parameter No.
1280.
Example) When 100 is set in parameter No. 1280
R0100 External machine zero point shift value for the 1st
axis (Low)
R0101 External machine zero point shift value for the 1st
axis (High)
R0102 External machine zero point shift value for the 2nd
axis (Low)
R0103 External machine zero point shift value for the 2nd
axis (High)
: :
R(0100+2(n-1)) External machine zero point shift value for the n-th
axis (Low)
R(0100+2(n-1)+1) External machine zero point shift value for the n-th
axis (High)
- Shift value
Specify a shift value by using a two-byte binary code for each axis.
A value from -32767 to 32767 can be specified.
A shift value is assumed to be specified as an absolute value.
The unit is the detection unit.
Example)
Suppose that the incremental system is IS-B, the machine is a
millimeter machine (bit 0 of parameter No. 1001 = 0),
the detection unit is 0.0002 mm (CMR (parameter No. 1820) =
10),
and parameter No. 1280 is set to 100.
When the following values are written to the R area :
R102 = 11001100 (CCh)