B-63943EN-1/02 1.AXIS CONTROL
- 61 -
1848 Value of the first stage of smooth backlash compensation
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] -9999 to 9999
Set the value of the first stage of smooth backlash compensation for
each axis.
If the setting of this parameter is larger than the total backlash
compensation value, smooth backlash compensation is not performed.
When a negative value is set for the backlash compensating value for
each axis (parameter No. 1851), set a negative value in this parameter.
If the sign set in this parameter is different from that set for the
backlash compensating value for each axis (parameter No. 1851),
compensation is performed, assuming that the value of the first stage
of smooth backlash compensation is “0”.