1.AXIS CONTROL B-63943EN-1/02
- 210 -
Diagnosis
The synchronization error and compensation are displayed on the
diagnostic screen.
3500 Synchronization error for each axis
[Unit of data] Detection unit
[Description] The difference between the positions of the master and slave axes
(synchronization error) is displayed.
It is displayed for the axis number of the slave axis.
3501 Synchronization error compensation for each axis
[Unit of data] Detection unit
[Description] The total number of compensation pulses output to the slave axis
(synchronization error compensation) is displayed. This number is
displayed for the axis number of the slave axis.
Alarm and message
Number Message Description
PS0213 ILLEGAL COMMAND IN
SYNCHRO-MODE
In feed axis synchronization control, the following errors occurred
during the synchronous operation.
1) The program issued the move command to the slave axis.
2) The program issued the manual operation to the slave axis.
3) The program issued the automatic reference position return
command without specifying the manual reference position
return after the power was turned on.
DS0001 SYNC EXCESS ERROR (POS DEV) In feed axis synchronization control, the difference in the amount
of positional deviation between the master and slave axes
exceeded the parameter (No. 8323) setting value.
This alarm occurs only for the slave axis.
DS0002 SYNC EXCESS ERROR ALARM 1 In feed axis synchronization control, the difference in the amount
of synchronization between the master and slave axes exceeded
the parameter (No. 8331) setting value.
This alarm occurs only for the slave axis.
DS0003 SYNCHRONIZE ADJUST MODE The system is in the synchronize adjust mode.
SV0001 SYNC ALIGNMENT ERROR In feed axis synchronization control, the amount of compensation
for synchronization exceeded the parameter (No. 8325) setting
value.
This alarm occurs only for a slave axis.
SV0002 SYNC EXCESS ERROR ALARM 2 In feed axis synchronization control, the amount of
synchronization error exceeded the parameter (No. 8332) setting
value. When the synchronization is not completed after
power-up, the determination is made by the parameter value (No.
8332) multiplied by the parameter (No. 8330) multiplier.
This alarm occurs only for a slave axis only.
SV0005 SYNC EXCESS ERROR (MCN) In feed axis synchronization control, for synchronization, the
difference value of the machine coordinate between a master
and slave axes exceeded the parameter (No. 8314) setting
value.