2.PREPARATIONS FOR OPERATION B-63943EN-1/02
- 360 -
All axes Interlock signal *IT<G008#0>
[Classification] Input signal
[Function] This signal is used to inhibit the machine from moving, and is
effective regardless of the selected mode.
[Operation] When the *IT signal is "0", the axis movement is decelerated and
stopped. In automatic operation, blocks containing M, S, T or B 2nd
auxiliary mode commands are executed consecutively until a block
containing an axis move command is encountered; the system then
stops and is placed into the automatic operation mode (cycle start
lamp signal STL is "1", feed hold lamp signal SPL is "0"). When the
*IT signal turns to "1", operation resumes (Figs. 2.5(c), (d)).
Command read
xis move
*IT
Fig. 2.5 (c) Block containing axis move commands only (manual and
automatic operation)
Command read
MF/SF/TF/BF
FIN
*IT
Fig. 2.5 (d) Block containing auxiliary functions only (automatic
operation)