B-63943EN-1/02 1.AXIS CONTROL
- 175 -
#7 #6 #5 #4 #3 #2 #1 #0
1008 RRLx RABx ROAx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 ROAx The roll-over function of a rotation axis is
0: Invalid
1: Valid
NOTE
ROAx specifies the function only for a rotation axis
(for which ROTx, #0 of parameter No.1006, is set to
1)
# 1 RABx In the absolute commands, the axis rotates in the direction
0: In which the distance to the target is shorter.
1: Specified by the sign of command value.
NOTE
RABx is valid only when ROAx is 1.
# 2 RRLx Relative coordinates are
0: Not rounded by the amount of the shift per one rotation
1: Rounded by the amount of the shift per one rotation
NOTE
1 RRLx is valid only when ROAx is 1.
2 Assign the amount of the shift per one rotation in
parameter No.1260.
1260 Amount of a shift per one rotation of a rotation axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] Degree
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B) )
(When the increment system is IS-B, 0.0 to +999999.999)
Set the amount of a shift per one rotation of a rotation axis.