B-63943EN-1/02 3.MANUAL OPERATION
- 425 -
#7 #6 #5 #4 #3 #2 #1 #0
7103 HNT
[Input type] Parameter input
[Data type] Bit path
# 3 HNT When compared with the travel distance magnification selected by the
manual handle feed travel distance selection signals (incremental feed
signals (MP1, MP2), the travel distance magnification for manual
handle interrupt is:
0: Same.
1: 10 times greater.
7113 Manual handle feed magnification m
[Input type] Parameter input
[Data type] Word path
[Valid data range] 1 to 2000
This parameter sets the magnification m when manual handle feed
movement selection signals MP1 and MP2 are set to 0 and 1.
7114 Manual handle feed magnification n
[Input type] Parameter input
[Data type] Word path
[Valid data range] 1 to 2000
This parameter sets the magnification when manual handle feed
movement selection signals MP1 and MP2 are set to 1.
7117
Allowable number of pulses that can be accumulated during manual handle
feed
[Input type] Parameter input
[Data type] 2-word path
[Unit of data] Pulse
[Valid data range] 0 to 999999999
This parameter sets the number of pulses from the manual pulse
generator that exceed the rapid traverse rate and can be accumulated
without being discarded if manual handle feed faster than the rapid
traverse rate is specified.
0:
The feedrate is clamped to the rapid traverse rate. Those handle
pulses that exceed the rapid traverse rate are ignored. (The scale
reading of the manual pulse generator may not match the travel
distance.)
Other than 0:
The feedrate is clamped to the rapid traverse rate. However,
those handle pulses that exceed the rapid traverse rate are not
ignored. In connection with the manual handle feed travel